HEIDENHAIN 230-01C3 - EMERGENCY STOP defective

EMERGENCY STOP defective

The internal or external EMERGENCY STOP circuit has a fault. This may involve relay switching delays, wiring issues, or a short circuit in the control-ready acknowledgment signal path.

Root Cause Summary

HEIDENHAIN alarm 230-01C3 indicates a malfunction in the emergency stop safety circuit, specifically excessive relay switching times or short circuits in the control-ready acknowledgment signals. This safety-critical alarm prevents machine operation until the emergency stop chain integrity is restored.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access PLC Status Display

    Navigate to MOD > PLC > Status to monitor emergency stop relay states K1, K2 and timing parameters.

    Use the oscilloscope function in PLC diagnostics to measure actual switching times

  2. 2

    Measure Relay Switching Times

    Check MC.RDY to I3 response time using TNC diagnostic functions - should be <200ms per Heidenhain safety specifications.

    Only qualified personnel should work on safety circuits

  3. 3

    Replace Emergency Stop Relay

    Replace the identified defective relay with Heidenhain-approved safety relay maintaining same part number and safety rating.

    Always replace relays in pairs to ensure matched switching characteristics

  4. 4

    Verify Safety Circuit Timing

    Perform complete emergency stop test cycle and verify all timing parameters meet TNC safety requirements in MOD > Machine > Safety.

    Document all safety circuit modifications per local safety regulations

Service Recommendedhigh confidence

Call a technician if:

  • ·Safety circuit modifications required
  • ·TNC internal module suspected
  • ·Timing measurements exceed specifications
  • ·Multiple emergency stop components failing

Prevention

  • Monthly emergency stop button function tests
  • Annual safety circuit timing verification
  • Regular inspection of emergency stop wiring for wear
  • Maintain emergency stop button cleanliness and lubrication

Common Mistakes

  • Bypassing safety circuits for troubleshooting
  • Using non-safety rated replacement components
  • Ignoring relay switching time specifications
  • Failing to document safety circuit modifications