axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
HEIDENHAIN 230-01CD - Incorrect connector assignment of the axis
Alarm 230-01CD occurs when the speed encoder input and PWM output connector assignments in the CC 424/CC 61xx control card parameters don't match the required fixed pairing. The TNC system enforces specific X-connector combinations where each speed encoder input must be paired with its corresponding PWM output.
HEIDENHAIN 230-01CD - Incorrect connector assignment of the axis
Incorrect connector assignment of the axis
The axis has an invalid connector assignment between the speed encoder input and PWM output. On CC 424 or CC 61xx controllers, these connections have fixed pairings that must be followed.
Root Cause Summary
Alarm 230-01CD occurs when the speed encoder input and PWM output connector assignments in the CC 424/CC 61xx control card parameters don't match the required fixed pairing. The TNC system enforces specific X-connector combinations where each speed encoder input must be paired with its corresponding PWM output.
Safety
Causes and Fixes
Access machine parameters
Navigate to MOD > Machine Parameters > Axis-specific parameters for the affected axis shown in %2.
Use PLC > Info > Axis assignment to verify which physical axis corresponds to %2
Check speedEncoderInput parameter
Locate MP7500 speedEncoderInput parameter and verify the assigned X-connector matches the required pairing (X15-X51, X16-X52, etc.).
Document current settings before making changes
Correct connector assignment
Change speedEncoderInput to match the corresponding pwmSignalOutput connector using the fixed pairing table.
Cross-reference with electrical drawings to ensure physical wiring matches parameter settings
Restart control
Perform a complete TNC restart to activate the new parameter settings and clear the alarm.
Ensure all programs are saved before restart
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.