HEIDENHAIN 230-02EE - The option for HSC filter has not been enabled

The option for HSC filter has not been enabled

An HSC filter was configured but the software option is not enabled. The system has automatically activated the triangle filter as a fallback.

Root Cause Summary

Alarm 230-02EE occurs when HSC (High Speed Cutting) filter parameters are configured in the servo settings but the HSC software option is not enabled in the control. The system automatically falls back to the triangle filter for the affected axis.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Software Options

    Access MOD function, select 'Software options' and verify if HSC filter option is listed and enabled.

    Look for option number 8 or HSC-related entries in the software options list

  2. 2

    Review Machine Parameters

    Check MP1420 (HSC filter frequency) and MP1421 (HSC filter damping) for configured values on the affected axis.

    Do not modify these parameters without understanding their impact on machining performance

  3. 3

    Contact Heidenhain for License

    If HSC filtering is required, contact Heidenhain service to purchase and activate the HSC software option.

    Have your control serial number and current software version ready when contacting service

DIY Feasiblehigh confidence

Call a technician if:

  • ·Software option purchase required
  • ·Servo instability after parameter changes
  • ·Hardware compatibility issues

Prevention

  • Verify software options before configuring advanced parameters
  • Document all parameter changes
  • Regular software license audits

Common Mistakes

  • Assuming HSC option is standard
  • Modifying parameters without checking software licensing
  • Not documenting original parameter values