Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

230-032C

HEIDENHAIN 230-032C - Axis: Supply module detected and registered

Axis: Supply module detected and registered

The supply module was automatically detected via plug-and-play and entered into the axis configuration. This confirms successful hardware recognition.

Root Cause Summary

HEIDENHAIN alarm 230-032C is an informational message indicating successful plug-and-play detection and registration of a supply module in the axis configuration. This typically occurs during system startup, hardware replacement, or configuration changes when the TNC control automatically identifies and registers power supply modules.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Verify System Status

    Check MOD function -> System Info -> Hardware to confirm all supply modules are properly detected and operational.

    This is typically an informational alarm that clears automatically after successful registration.

  2. 2

    Review Configuration

    Navigate to MOD -> Machine Parameters -> CfgSupplyModule to verify the detected module appears with correct name and parameters.

    Document the module serial number and configuration for future reference.

  3. 3

    Clear Alarm

    Press CE key to acknowledge the informational alarm after verifying proper module registration.

    Only clear after confirming the supply module is functioning correctly.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Supply module fails operational tests after registration
  • ·Repeated communication failures
  • ·Multiple supply modules showing registration issues

Prevention

  • Maintain stable power supply to control cabinet
  • Perform regular parameter backups
  • Keep communication cables properly secured
  • Monitor drive diagnosis logs for early warning signs

Common Mistakes

  • Treating informational alarm as critical error
  • Clearing alarm without verifying module operation
  • Not updating parameter backups after module replacement
  • Ignoring underlying communication issues

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.