Heidenhain codes
HeidenhainSpindleIntermediate30-120 minutes

230-0198

HEIDENHAIN 230-0198 - Nominal speed value too high

Nominal speed value too high

The calculated speed command is too high for the axis or spindle hardware. On analog drives this means over +-10V; on digital drives it exceeds the motor maximum. The machine may also fail to follow acceleration ramps.

Root Cause Summary

Heidenhain alarm 230-0198 occurs when the calculated nominal speed value exceeds the maximum allowable limits for the servo system. This typically results from incorrect machine parameter settings, excessive programmed feed rates, or hardware issues in the control loop that prevent proper speed regulation.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Maximum Speed Parameters

    Access MOD function, select Machine Parameters, navigate to MP1020 (spindle) or MP1021 (axis) and verify maximum speed settings match motor specifications.

    Compare MP values with motor nameplate data - many issues stem from incorrect parameter entry during commissioning.

  2. 2

    Verify Current Program Feed Rate

    Check active NC program for excessive F values or rapid traverse rates that exceed calculated machine capabilities based on MP1020/MP1021 settings.

    Never increase maximum speed parameters without verifying mechanical system capabilities and safety interlocks.

  3. 3

    Test with Reduced Feed Override

    Set feed rate override to 25% and attempt program execution to confirm if alarm clears, indicating feed rate exceeds machine parameter limits.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Hardware encoder or drive faults confirmed
  • ·Parameter changes don't resolve alarm
  • ·Multiple axes affected simultaneously

Prevention

  • Regularly verify machine parameters match actual hardware specifications
  • Monitor feed rate programming to stay within machine capabilities
  • Perform periodic encoder signal quality checks

Common Mistakes

  • Increasing maximum speed parameters without considering mechanical limits
  • Ignoring acceleration ramp relationships to maximum speed
  • Assuming all axes have identical speed capabilities