Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

230-01A0

HEIDENHAIN 230-01A0 - Axis index on CC too large

Axis index on CC too large

The axis index assigned by selEncoderIn points to a CC that has fewer axes than the configuration claims. The encoder input is out of range for the chosen controller.

Root Cause Summary

HEIDENHAIN alarm 230-01A0 occurs when the selEncoderIn parameter references an axis index that exceeds the number of axes physically configured on the CC (Compact Controller). This typically happens after hardware changes or incorrect parameter configuration during system setup.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access CC configuration parameters

    Navigate to MOD > Configuration > Machine Parameters > CC Parameters and locate the selEncoderIn parameter settings.

    Document current parameter values before making changes

  2. 2

    Verify axis count on CC module

    Check the physical CC module specifications and count the actual number of axis connections available on the hardware.

    Ensure machine is in safe state before accessing hardware

  3. 3

    Correct selEncoderIn parameter

    Modify the selEncoderIn parameter to reference only valid axis indices (typically 0-based counting, so for 3 axes use 0,1,2).

    Cross-reference with MP7500 series parameters for axis assignment

  4. 4

    Restart CC module

    Perform a controlled restart of the CC module through MOD > Reset > CC Reset to apply parameter changes.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter corruption persists after default reload
  • ·Hardware replacement required
  • ·Firmware downgrade needed

Prevention

  • Always backup parameters before hardware changes
  • Verify CC module specifications before replacement
  • Document encoder-to-axis mapping for future reference
  • Implement regular parameter backup schedule

Common Mistakes

  • Assuming axis indexing starts at 1 instead of 0
  • Not checking CC module axis count after replacement
  • Modifying selEncoderIn without understanding hardware limits
  • Forgetting to restart CC module after parameter changes

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.