HEIDENHAIN 230-01A4 - EnDat encoder reports different resolution

EnDat encoder reports different resolution

The resolution reported by the connected EnDat encoder differs from the value stored in the configuration. This mismatch causes scaling errors.

Root Cause Summary

HEIDENHAIN alarm 230-01A4 occurs when the EnDat encoder's actual resolution differs from the configured resolution in the TNC control parameters. This mismatch prevents proper position feedback and axis initialization during the startup sequence.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine parameters

    Press MOD key, select 'Machine Parameters', navigate to MP2410.x where x is the axis number from the alarm message.

    Always note the current value before making changes for rollback purposes

  2. 2

    Verify encoder specification

    Check the encoder nameplate or documentation for the correct resolution (typically 1024, 2048, 4096, or higher increments per revolution).

    Never guess the resolution - incorrect values can cause axis runaway

  3. 3

    Update MP2410 parameter

    Enter the correct encoder resolution value in MP2410.x and confirm the entry. Perform a control restart to activate the new parameter.

    Use the encoder's native resolution without any multiplication factors

  4. 4

    Verify axis initialization

    Monitor the startup sequence to confirm the alarm clears and the axis initializes properly without position errors.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Drive amplifier hardware failure
  • ·Multiple axes affected simultaneously

Prevention

  • Regular backup of machine parameters
  • Periodic encoder cable inspection
  • EMI source identification and mitigation
  • Proper documentation of encoder specifications

Common Mistakes

  • Guessing encoder resolution values
  • Ignoring EMI sources during troubleshooting
  • Not backing up parameters before changes
  • Mixing up encoder specifications between similar machines