HEIDENHAIN 230-01AD - Deviation in the switch-on position of axis too large

Deviation in the switch-on position of axis too large

After power-on, the axis position differs from the last saved value by more than the tolerance set in CfgReferencing->endatDiff.

Root Cause Summary

Alarm 230-01AD occurs when the encoder's absolute position at power-on differs from the last saved position by more than the tolerance set in CfgReferencing->endatDiff. This indicates potential mechanical movement, encoder issues, or parameter corruption since the last shutdown.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check mechanical constraints

    Inspect brake systems, clamps, and counterbalances. Verify axis brake engagement in MOD function 'Axis diagnosis' menu.

    Ensure machine is in safe state before checking mechanical components

  2. 2

    Measure actual deviation

    In Setup->CfgReferencing, check the current endatDiff value and compare with actual position deviation shown in alarm details.

    Document the deviation amount - consistent values indicate systematic mechanical issues

  3. 3

    Perform controlled reference run

    Execute manual reference point approach via Setup->CfgReferencing->Reference. Monitor for smooth movement and proper brake release.

    Clear work area and verify axis travel limits before referencing

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Persistent communication errors after cable replacement
  • ·Mechanical axis binding detected

Prevention

  • Regular encoder battery monitoring
  • Proper axis brake maintenance
  • Environmental protection of encoder cables
  • Periodic endatDiff parameter review

Common Mistakes

  • Setting endatDiff too large compromising accuracy
  • Ignoring mechanical root causes
  • Replacing encoder without checking battery first
  • Not documenting parameter changes