Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0197

HEIDENHAIN 230-0197 - Error in zero pulse distance of encoder

Error in zero pulse distance of encoder

This TNC7/TNC 640 error indicates an issue with 230-0197. Contradiction in comparison of the absolute and incremental position.

Root Cause Summary

Alarm 230-0197 occurs when the TNC control detects a discrepancy between the absolute encoder position and the incremental position count, indicating a loss of reference position integrity. This typically results from encoder hardware failure, contamination, or electrical interference affecting the zero pulse signal.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Clean encoder components

    Power down machine and clean encoder scale/disk with isopropyl alcohol and lint-free cloth. Check for physical damage to encoder housing.

    Ensure machine is fully powered down and locked out before accessing encoder components

  2. 2

    Inspect encoder mounting

    Check encoder mounting screws for looseness and verify proper gap between read head and scale (typically 0.1-0.5mm for Heidenhain encoders).

    Use feeler gauges to verify exact gap specification from encoder datasheet

  3. 3

    Test encoder signals

    Access Service menu > Encoder test and monitor signal quality while manually moving axis. Look for consistent zero pulse detection.

    Signal amplitude should be within ±10% of nominal values

DIY Feasiblemedium confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Multiple axes affected simultaneously
  • ·Persistent alarm after cable and cleaning

Prevention

  • Regular encoder cleaning schedule
  • Proper cable management and protection
  • Periodic encoder signal quality monitoring

Common Mistakes

  • Ignoring encoder gap specifications
  • Using incorrect cleaning solvents
  • Powering system during encoder cable work

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.