Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

210-001C

HEIDENHAIN 210-001C - Incorrect binary data in system file (entity)

Incorrect binary data in system file (entity)

This TNC7/TNC 640 error (210-001C) relates to 'Incorrect binary data in system file (entity)'. Error during binary transmission of a message.

Root Cause Summary

HEIDENHAIN alarm 210-001C indicates corrupted binary data transmission between system components, typically during file transfer operations or communication with external devices. This alarm occurs when the TNC control detects data integrity errors in system files or during binary message exchanges.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access file management

    Press MOD key, select 'File management' and navigate to the problematic system file location.

    Check file size - corrupted files often show unusual byte counts

  2. 2

    Verify backup source

    Compare original backup file on external media with transferred file using 'File info' function in TNC file manager.

    Do not overwrite working system files without verified backup

  3. 3

    Re-transfer system file

    Delete corrupted file and re-transfer from known good backup source, ensuring proper file extension (.SYS) is maintained.

    Use TNC's built-in checksum verification when available

  4. 4

    Restart control system

    Perform controlled restart via MOD > System > Restart to reload system files and clear alarm condition.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Memory diagnostic shows hardware failure
  • ·System recovery procedures fail
  • ·Repeated alarm occurrence after all troubleshooting steps

Prevention

  • Regularly backup system files and MP tables
  • Use high-quality CF cards and USB storage devices
  • Maintain stable network connections for DNC operations
  • Perform periodic file system integrity checks

Common Mistakes

  • Ignoring file size discrepancies during transfers
  • Using quick format instead of full format on storage devices
  • Not verifying backup integrity before system recovery
  • Mixing different TNC software versions in backup/restore operations

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.