HEIDENHAIN 220-0018 - General internal communication error
This alarm stems from a failure in the internal data exchange between the TNC's central processing unit and critical subsystems like the PLC controller or axis processors. Most commonly, this is caused by hardware connection issues with internal modules, firmware incompatibilities after updates, or actual component failure on the MC or CC boards. Power instability and low buffer battery voltage can also corrupt communication protocols.
HEIDENHAIN 220-0018 - General internal communication error
General internal communication error
This TNC7/TNC 640 error (220-0018) relates to 'General internal communication error'. An error has occurred in the system-inherent communica- tion.
Root Cause Summary
This alarm stems from a failure in the internal data exchange between the TNC's central processing unit and critical subsystems like the PLC controller or axis processors. Most commonly, this is caused by hardware connection issues with internal modules, firmware incompatibilities after updates, or actual component failure on the MC or CC boards. Power instability and low buffer battery voltage can also corrupt communication protocols.
Safety
Causes and Fixes
Power Down and Access Control Cabinet
Safely power down the machine and TNC control. Lock out electrical supply and wait 2 minutes for capacitor discharge before opening the control cabinet.
High voltage remains in control components after shutdown. Follow all lockout/tagout procedures.
Reseat CC Module
Locate the CC module on the backplane (typically labeled CC or PLC). Carefully remove the module by releasing locking clips, inspect connectors for corrosion or damage, then firmly reseat ensuring full engagement with audible click.
Mark connector orientation before removal. Clean connector contacts with isopropyl alcohol if any discoloration is visible.
Inspect Backplane Connector
Examine the backplane connector pins for bent contacts, burn marks, or debris. Use compressed air to clean the connector area and ensure no foreign material is present.
Never use contact cleaners with oil or residue on control components.
Power Up and Test
Restore power and monitor startup sequence. If alarm clears, run a complete PLC cycle test and axis reference run to verify stable communication.
If alarm clears temporarily but returns, the CC module itself is likely failing and requires replacement.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.