HEIDENHAIN 220-001B - Cannot close queue

Cannot close queue

The control could not close an internal system queue. This is a system-level communication fault that may leave resources in an inconsistent state.

Root Cause Summary

HEIDENHAIN alarm 220-001B occurs when the TNC control cannot properly close an internal communication queue, typically due to network interface problems, PLC communication errors, or system resource conflicts. This alarm indicates a breakdown in the control's internal message handling system that manages data flow between different system components.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Network Interface Status

    Navigate to MOD function → System Info → Network Status and verify Ethernet interface X116 shows 'Connected' status with valid IP configuration.

    Look for packet loss counters or error statistics in the network diagnostics

  2. 2

    Reset Network Interface

    Access Setup → General → Network Settings, disable and re-enable the Ethernet interface, then restart the TNC control completely.

    Save all active programs before restarting the control

  3. 3

    Verify Cable Connections

    Check physical Ethernet cable connection at X116 connector and verify network switch/router connectivity with ping test from TNC terminal.

    Use TNC's built-in ping utility in MOD function → System → Network Tools

  4. 4

    Check Network Parameters

    Verify MP7200 (Network Configuration) parameters match your network requirements and MP7210 (IP Address) is not conflicting with other devices.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Alarm persists after network and PLC resets
  • ·Multiple communication alarms occur simultaneously
  • ·System memory consistently shows critical levels

Prevention

  • Regularly monitor network interface statistics
  • Implement proper LSV2 connection management in external software
  • Schedule periodic PLC cycle time monitoring
  • Maintain adequate free disk space for system operations

Common Mistakes

  • Ignoring network cable quality and connections
  • Not properly configuring LSV2 timeout parameters
  • Running too many simultaneous external connections
  • Clearing the alarm without addressing the underlying communication issue