HEIDENHAIN 221-006F - Faulty kinematics configuration Active kinematics contains an invalid insertion point.
The active kinematic transformation definition contains a reference to an insertion point that either does not exist in the configuration file or is improperly defined. This typically results from corrupted configuration files, manual editing errors, or incomplete kinematic data after configuration changes. The control cannot establish the proper kinematic chain without valid insertion point definitions at all referenced locations.
HEIDENHAIN 221-006F - Faulty kinematics configuration Active kinematics contains an invalid insertion point.
Faulty kinematics configuration Active kinematics contains an invalid insertion point.
The active kinematic model includes an invalid insertion point for a tool-carrier sub-model under CfgKinToolSocket. Only one such socket is allowed, and it must sit at the correct place in the chain.
Root Cause Summary
The active kinematic transformation definition contains a reference to an insertion point that either does not exist in the configuration file or is improperly defined. This typically results from corrupted configuration files, manual editing errors, or incomplete kinematic data after configuration changes. The control cannot establish the proper kinematic chain without valid insertion point definitions at all referenced locations.
Safety
Causes and Fixes
Identify active kinematic number
Press MOD key, navigate to Machine Parameters, and note the kinematic number shown in alarm %1. This identifies which KINEMATICSXXX.CFG file is problematic.
Write down the exact kinematic number - it will be needed to locate the correct configuration file.
Access kinematic configuration file
In Programming and Editing mode, press PGM MGT key, navigate to TNC:\system\Kinematic\ directory and open the corresponding KINEMATICSXXX.CFG file for inspection.
Do not edit system files unless you have proper backup and authorization from machine tool builder.
Verify insertion point definitions
Search for 'INSERTION_POINT' entries in the configuration file. Check that every insertion point index referenced in the kinematic chain (typically 0, 1, 2, etc.) has a complete definition block with position and orientation data.
Valid insertion point definitions must include position vectors and proper syntax. Missing brackets, commas, or values will trigger this alarm.
Restore from backup or factory default
If insertion point definitions are missing or corrupted, restore the kinematic configuration from a known good backup. If unavailable, contact the machine tool builder for the correct configuration file for your specific machine model.
Never use kinematic files from different machine models - this can cause crashes and damage.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.