HEIDENHAIN 220-0025 - Contradictory data during PLC strobe implementation

Contradictory data during PLC strobe implementation

A PLC strobe implemented through a macro produced internally inconsistent data. The message fields contradict each other, making the strobe unusable.

Root Cause Summary

Alarm 220-0025 occurs when contradictory data is detected during PLC strobe implementation with macro execution. This typically happens when macro parameters conflict with PLC interface signals or when invalid data combinations are passed through the PLC strobe mechanism.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check macro parameter values

    Navigate to Programming and Operating > Program Run > PLC and examine the macro call parameters in the PLC strobe. Verify Q-parameter assignments for logical consistency.

    Use the macro trace function to monitor parameter flow during execution

  2. 2

    Validate parameter ranges

    Check that all macro parameters fall within valid ranges defined in machine parameters MP7440-MP7459 (PLC interface parameters). Ensure no parameters exceed maximum values.

    Invalid parameters can cause unpredictable machine behavior

  3. 3

    Review macro logic

    Examine the macro code for conditional statements that might create contradictory parameter assignments based on current machine state or input conditions.

DIY Feasiblemedium confidence

Call a technician if:

  • ·PLC programming modifications required
  • ·Memory mapping changes needed
  • ·Persistent alarm after parameter adjustments

Prevention

  • Validate all macro parameters before PLC strobe implementation
  • Use consistent timing parameters for PLC interface
  • Regular backup of PLC memory mapping configuration

Common Mistakes

  • Ignoring PLC strobe timing requirements
  • Using incompatible macro commands in PLC-called routines
  • Insufficient memory access permissions for PLC interface