HEIDENHAIN 210-001B - Incorrect binary data in system file (array)

Incorrect binary data in system file (array)

This TNC7/TNC 640 error (210-001B) relates to 'Incorrect binary data in system file (array)'. Error during binary transmission of an array in a message.

Root Cause Summary

HEIDENHAIN alarm 210-001B occurs when binary data transmission fails during array operations in system files, typically during PLC communication or data exchange between TNC control and external systems. This alarm indicates corrupted or incomplete binary data packets during message transmission.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PLC Status

    Navigate to MOD function → PLC → Status display to verify PLC communication status and check for buffer overflow indicators.

    Look for cyclic data exchange errors in the PLC status window

  2. 2

    Verify Array Size Parameters

    Access machine parameter MP7680 (PLC data exchange) and verify that array dimensions match the configured buffer sizes in the PLC program.

    Incorrect buffer sizes can cause system instability

  3. 3

    Reset PLC Communication

    Execute PLC RESET via MOD function → PLC → Reset to clear communication buffers and reinitialize data exchange.

    Perform reset during machine idle time to avoid program interruption

  4. 4

    Monitor Data Exchange

    Use PLC trace function to monitor binary data transmission and verify array data integrity during next communication cycle.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Memory diagnostics show hardware failures
  • ·Multiple system files corrupted
  • ·Network infrastructure changes required

Prevention

  • Regular system file backups
  • Network cable inspection during PM
  • Monitor PLC buffer utilization
  • Maintain stable operating temperatures

Common Mistakes

  • Ignoring network diagnostics
  • Restoring incompatible backup versions
  • Overlooking PLC program array size limits
  • Not verifying power supply stability