Heidenhain Controller
System · Intermediate · 30-120 minutes
HEIDENHAIN 140-0044 - Shut down and restart the control
This alarm is triggered by the TNC control system when configuration data affecting the real-time operating system, hardware interface layer, or PLC runtime environment has been modified. The control cannot hot-load these changes and requires a complete reboot cycle to reinitialize the system with the new configuration parameters stored in non-volatile memory.
HEIDENHAIN 140-0044 - Shut down and restart the control
Shut down and restart the control
The trial period has ended and the license is now inactive. Features that were temporarily available will continue working only until the next system restart.
Root Cause Summary
This alarm is triggered by the TNC control system when configuration data affecting the real-time operating system, hardware interface layer, or PLC runtime environment has been modified. The control cannot hot-load these changes and requires a complete reboot cycle to reinitialize the system with the new configuration parameters stored in non-volatile memory.
Safety
Causes and Fixes
Verify PLC Changes
Press MOD key, select PLC Programming, check if recent edits were made. Look for modified timestamp on plc.mkd file in PLC directory.
Always document PLC changes in the comment header section with date and modification description for future troubleshooting.
Save All Active Programs
Before shutdown, ensure all active NC programs are saved. Press PGM MGT key and verify current program status.
Unsaved program changes in the editor will be lost during shutdown.
Perform Controlled Shutdown
From main screen, select Operating Mode key > Control Shutdown. Wait for 'Control can now be switched off' message before cycling power.
Cold Restart Control
Cycle main control power OFF for minimum 10 seconds, then power ON. Monitor boot sequence on screen for any additional errors.
Verify PLC Functionality
After restart, press MOD > PLC Programming > PLC Monitor to verify PLC is running and check M/W markers are functioning correctly.
Use PLC trace function to monitor critical I/O signals immediately after restart to confirm proper initialization.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.