140-0034

HEIDENHAIN 140-0034 - Data object moved to file

Data object moved to file

The loaded configuration data is from an older NC software version. A data object was saved in the wrong file and has been moved according to update rules.

Root Cause Summary

This message indicates the TNC control has automatically preserved a data object by moving it to an archive or backup file. This is a protective measure performed during system maintenance, updates, or when the control detects potential data integrity issues. The original data is safeguarded and can be restored if needed.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Confirm Update Activity

    Press MOD key → Software Version Info to check if a recent software update occurred. Compare displayed version with previous known version.

    TNC controls always create timestamped backups during updates. The filename in '%3' typically includes a date/time stamp.

  2. 2

    Verify Data Object Integrity

    Access the data object type indicated in '%1' (e.g., if 'Tool Table', press TOOL TABLE key; if 'Preset Table', press POS key). Verify all entries are present and correct.

    After updates, the control may migrate data formats. The moved file represents the pre-migration version.

  3. 3

    Locate and Document Backup

    Press MOD → File Management, navigate to the path shown in '%3'. Note the backup file location and size for future reference.

    Standard backup location is typically TNC:\system\backup\ or TNC:\backup\ depending on control generation.

  4. 4

    Test Machine Operation

    Perform a dry run test of a known program to verify tool data, offsets, and presets function correctly with the current active data objects.

    Use dry run mode with feed override at 0% initially to verify correct tool selection and offset application.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration files are corrupted beyond recovery
  • ·Machine parameters are lost after migration
  • ·Servo axes fail to function after data migration

Prevention

  • Always backup machine parameters before software updates
  • Use compatible TNCremo versions for data transfer
  • Regularly check file system integrity
  • Document software version history

Common Mistakes

  • Ignoring the alarm as purely informational without verification
  • Manually moving configuration files
  • Not backing up parameters before software updates
  • Using incompatible TNCremo versions