Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

140-0036

HEIDENHAIN 140-0036 - Value of data object was changed. Attribute.

Value of data object was changed. Attribute.

The loaded configuration data is from an older NC software version. One or more attribute values were changed by update rules.

Root Cause Summary

This message indicates that a configuration data object in the TNC's internal system database has been modified. The change could be deliberate (through commissioning work, parameter optimization) or unexpected (software update side effect, accidental modification). The alarm serves as an audit trail to track configuration changes on the control.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Review the specific change details

    Press RECALL key to display full alarm text showing the data object name ('%1'), the changed value ('%2'), and the affected attribute ('%3'). Note these details for verification.

    The attribute name often indicates the category (e.g., 'CfgAxisLinear', 'CfgSpindle', 'CfgEnc') which helps identify the affected system area.

  2. 2

    Access Configuration Editor

    Navigate to MOD → 13 (System Parameters) → Configuration Editor. Search for the data object name shown in the alarm message to view current settings.

    Changes in Configuration Editor require appropriate password level (typically OEM or higher). Incorrect modifications can affect machine behavior.

  3. 3

    Verify change was intentional

    Compare the new value against machine documentation or consult with the person who performed maintenance. Check timestamp of change in system log.

    Access system log via MOD → TNC System Info → Event Log to see exact time and user context of parameter change.

  4. 4

    Clear informational message

    If change is verified as correct, acknowledge the message by pressing CE (Clear Error) key. The message serves only as notification, not as operational alarm.

    Document accepted changes in machine commissioning records for future reference and traceability.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Servo parameters show significant deviations from expected values
  • ·Machine exhibits positioning errors after parameter updates
  • ·PLC program fails to start after configuration update

Prevention

  • Always backup current configuration before software updates
  • Maintain version-specific parameter files for each software level
  • Document all custom parameter modifications for future reference

Common Mistakes

  • Ignoring the alarm without verifying parameter changes
  • Assuming all automatic conversions are correct without validation
  • Not backing up the updated configuration after successful conversion

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.