Haas 271 - C SERVO OVERLOAD | Haas CNC Alarm
Alarm 271 DC Bus Low occurs when the rectified DC voltage in the servo drive power supply drops below the minimum threshold, typically due to incoming AC power issues, power supply component failure, or excessive load conditions. This protective alarm prevents servo amplifier damage by shutting down motor operation when insufficient DC bus voltage is detected.
Haas 271 - C SERVO OVERLOAD | Haas CNC Alarm
C SERVO OVERLOAD
This alarm is triggered when the C-axis servo amplifier detects continuous excessive current draw that exceeds thermal limits for an extended period. The servo amp monitors motor current and calculates accumulated heat in the motor windings, shutting down when the thermal model indicates overload conditions. This protects both the servo motor and amplifier from damage due to sustained overwork.
Root Cause Summary
Alarm 271 DC Bus Low occurs when the rectified DC voltage in the servo drive power supply drops below the minimum threshold, typically due to incoming AC power issues, power supply component failure, or excessive load conditions. This protective alarm prevents servo amplifier damage by shutting down motor operation when insufficient DC bus voltage is detected.
Safety
Causes and Fixes
Check Incoming AC Voltage
Use multimeter to measure all three phases at the main disconnect. Verify 208-240V systems have 200-250V per phase, 460-480V systems have 440-500V per phase.
Use proper PPE and lockout procedures when measuring high voltage
Verify Phase Balance
Measure voltage between all phase combinations (L1-L2, L2-L3, L1-L3). Voltage imbalance should be less than 2% between phases.
Phase imbalance over 3% can cause DC bus instability even with acceptable individual phase voltages
Check Power Quality
Monitor voltage stability under load using oscilloscope or power quality analyzer. Look for voltage sags, spikes, or harmonic distortion during machining operations.
Inspect Electrical Connections
Check all incoming power connections at main disconnect, transformer, and machine input terminals for looseness, corrosion, or overheating signs.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.