Fanuc 574 - Spindle coolant pressure error

SPINDLE COOLANT PRESSURE ERROR

Fanuc spindle alarm 574: SPINDLE COOLANT PRESSURE ERROR. The spindle drive or spindle motor has detected a fault condition that requires diagnosis before spindle operation can resume.

Root Cause Summary

Alarm 574 indicates the through-spindle coolant system pressure has fallen below the minimum threshold required for safe operation, or the pressure monitoring circuit has failed. This alarm protects the spindle and tooling from inadequate coolant flow during high-pressure coolant operations.

Safety

  • Verify corrected program or parameters before resuming machining

Causes and Fixes

  1. 1

    Check coolant tank level and refill if below minimum. Verify pump is running when M-code commands coolant on.

  2. 2

    Inspect and clean or replace the coolant filters. Clogged filters are a common cause of pressure loss.

  3. 3

    Check all coolant lines, fittings, rotary union, and through-tool connections for leaks or damage. Tighten or replace as needed.

    Use proper PPE when working with high-pressure coolant systems

  4. 4

    Verify coolant pump operation and pressure output with a gauge. Compare against machine specifications (typically 20-70 bar depending on system).

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.