Fanuc Alarm 5064 - DIFFERENT AXIS UNIT (IS-B, IS-C)
Alarm 5064 occurs when there is a mismatch in axis unit configuration between IS-B (αi series servo) and IS-C (βi series servo) amplifier types within the same system. This typically happens during mixed amplifier installations, parameter restoration after hardware changes, or incorrect parameter settings in IS-B/IS-C mixed servo configurations where unit settings must be consistent across all axes.
Fanuc Alarm 5064 - DIFFERENT AXIS UNIT (IS-B, IS-C)
SYSTEM ALARM 5064
Fanuc alarm 5064: SYSTEM ALARM 5064. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 5064 occurs when there is a mismatch in axis unit configuration between IS-B (αi series servo) and IS-C (βi series servo) amplifier types within the same system. This typically happens during mixed amplifier installations, parameter restoration after hardware changes, or incorrect parameter settings in IS-B/IS-C mixed servo configurations where unit settings must be consistent across all axes.
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameter 1022 (unit type) for all axes. Verify IS-B axes (typically older αi amplifiers) and IS-C axes (βi amplifiers) have matching unit settings (0=metric, 1=inch).
Check parameter 1006#0 (IS-C specification) and parameter 1815 (servo specification) to confirm which axes are configured as IS-B versus IS-C. Cross-reference with physical amplifier models installed.
If mixing amplifier types, ensure parameter 8132 (reference counter unit) and parameter 1820 (position detector setting) are consistently configured across all axes with compatible resolution settings.
Changing unit parameters requires careful recalibration of pitch error compensation and reference position data
After correcting unit parameters, perform SYSTEM > PARAM write, power cycle the entire system, and verify via DIAGNOSIS > SERVO to confirm all axes show consistent unit configuration without alarm recurrence.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.