Fanuc Alarm 5073 - NO DECIMAL POINT
Fanuc alarm 5073 NO DECIMAL POINT occurs when a G-code or MDI command requires a decimal point specification but none was provided. This typically affects feedrate commands (F), spindle speed commands (S), or coordinate values where the control expects explicit decimal notation based on parameter settings or address word requirements.
Fanuc Alarm 5073 - NO DECIMAL POINT
SYSTEM ALARM 5073
Fanuc alarm 5073: SYSTEM ALARM 5073. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc alarm 5073 NO DECIMAL POINT occurs when a G-code or MDI command requires a decimal point specification but none was provided. This typically affects feedrate commands (F), spindle speed commands (S), or coordinate values where the control expects explicit decimal notation based on parameter settings or address word requirements.
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameter 3401 bit 0 (DPI). If DPI=1, all F and S codes require decimal point notation (e.g., F100.0 not F100).
Review the alarm line number displayed on screen and examine the part program or MDI command at that line for F or S codes without decimal points.
Correct the program by adding decimal points to all F and S codes (e.g., change F500 to F500.0, S1200 to S1200.0).
If parameter 3401#0=0 but alarm persists, verify parameter 3405 (F code input unit) is not set to require decimal notation for fractional feedrates.
Call a technician if: