Fanuc Alarm 507 - 4th Axis Negative Overtravel

Overtravel -4th

Axis overtravel -4th limit triggered. The machine has reached the software or hardware travel limit in the indicated direction.

Root Cause Summary

Fanuc alarm 507 OVER TRAVEL -n (HARDWARE) indicates the n-th axis has physically contacted the negative direction hardware overtravel limit switch (OT-). This is a hard limit condition caused by mechanical motion beyond safe travel limits, limit switch misalignment, faulty switch/wiring, or incorrect parameter settings for stored stroke limits and reference position.

Safety

  • Jog slowly away from limit

Causes and Fixes

  1. 1

    Check DIAGNOSIS screen > #300-#307 (DGN for I/O status) to verify which axis limit switch is active. Look for OT- signal for the indicated axis n showing '1' status, confirming hardware switch activation.

  2. 2

    Check POSITION screen (ABSOLUTE, MACHINE coordinates) to determine exact axis position. Compare against parameter #1320-#1327 (stored stroke limit negative) to verify axis is beyond expected travel range.

  3. 3

    If machine has absolute encoder (serial or Ai), place mode selector to JOG and carefully jog axis in positive direction away from limit switch. Monitor DIAGNOSIS screen to confirm OT- signal turns off as axis clears the switch.

    Proceed slowly with manual feed override reduced to 10-25%. Ensure no mechanical obstructions exist before jogging.

  4. 4

    After clearing hardware limit, execute reference position return (zero return) for the affected axis to re-establish machine coordinates. Verify reference position parameter #1815 (reference position return check) = 0 or 1, then verify stored stroke check parameters #1320-#1327 are correctly set to prevent recurrence.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder feedback problems persist
  • ·Mechanical binding cannot be resolved
  • ·Servo amplifier shows fault codes
  • ·Hardware limit switches are damaged

Prevention

  • Regular verification of soft limit parameters
  • Proper work coordinate system management
  • Routine reference return procedures
  • Regular mechanical inspection of rotary axis

Common Mistakes

  • Disabling software limits to 'fix' the problem
  • Forcing axis movement without identifying root cause
  • Ignoring position drift warnings
  • Setting soft limits too close to hardware limits

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.