Fanuc Alarm 507 - 4th Axis Negative Overtravel
Fanuc alarm 507 OVER TRAVEL -n (HARDWARE) indicates the n-th axis has physically contacted the negative direction hardware overtravel limit switch (OT-). This is a hard limit condition caused by mechanical motion beyond safe travel limits, limit switch misalignment, faulty switch/wiring, or incorrect parameter settings for stored stroke limits and reference position.
Fanuc Alarm 507 - 4th Axis Negative Overtravel
Overtravel -4th
Axis overtravel -4th limit triggered. The machine has reached the software or hardware travel limit in the indicated direction.
Root Cause Summary
Fanuc alarm 507 OVER TRAVEL -n (HARDWARE) indicates the n-th axis has physically contacted the negative direction hardware overtravel limit switch (OT-). This is a hard limit condition caused by mechanical motion beyond safe travel limits, limit switch misalignment, faulty switch/wiring, or incorrect parameter settings for stored stroke limits and reference position.
Safety
Causes and Fixes
Check DIAGNOSIS screen > #300-#307 (DGN for I/O status) to verify which axis limit switch is active. Look for OT- signal for the indicated axis n showing '1' status, confirming hardware switch activation.
Check POSITION screen (ABSOLUTE, MACHINE coordinates) to determine exact axis position. Compare against parameter #1320-#1327 (stored stroke limit negative) to verify axis is beyond expected travel range.
If machine has absolute encoder (serial or Ai), place mode selector to JOG and carefully jog axis in positive direction away from limit switch. Monitor DIAGNOSIS screen to confirm OT- signal turns off as axis clears the switch.
Proceed slowly with manual feed override reduced to 10-25%. Ensure no mechanical obstructions exist before jogging.
After clearing hardware limit, execute reference position return (zero return) for the affected axis to re-establish machine coordinates. Verify reference position parameter #1815 (reference position return check) = 0 or 1, then verify stored stroke check parameters #1320-#1327 are correctly set to prevent recurrence.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.