Fanuc Alarm 355 - PARAMETER OF INDEX OF COMPOSITE CONTROL AXIS SET ERROR
Alarm 355 COMPOSITE CONTROL AXIS SET ERROR occurs when parameter No. 8183 contains an invalid axis number or configuration for composite control (tandem/synchronous control). This typically happens during initial setup, after axis reconfiguration, or when parameter data becomes corrupted. The composite control axis specified does not match available physical axes or violates composite control pairing rules.
Fanuc Alarm 355 - PARAMETER OF INDEX OF COMPOSITE CONTROL AXIS SET ERROR
PARAMETER OF INDEX OF COMPOSITE CONTROL AXIS SET ERROR
Fanuc PS355: The parameter setting for composite control axis index has an error. The axis pair configured for composite control has an invalid parameter value.
Root Cause Summary
Alarm 355 COMPOSITE CONTROL AXIS SET ERROR occurs when parameter No. 8183 contains an invalid axis number or configuration for composite control (tandem/synchronous control). This typically happens during initial setup, after axis reconfiguration, or when parameter data becomes corrupted. The composite control axis specified does not match available physical axes or violates composite control pairing rules.
Causes and Fixes
Navigate to SYSTEM > PARAM and verify parameter 0020 (number of controlled axes). Note the total axes configured.
Check parameter 8183 (composite control axis number). Verify the value does not exceed the number in parameter 0020 and is a valid axis number (1-8 for most systems, 1-24 for 30i/31i/32i).
Parameter write enable (PWE) must be set to 1 before modifying parameters. Record original values before changes.
If parameter 8183 contains an invalid axis number, correct it to match the intended composite axis (typically the slave axis in tandem control). Set to 0 if composite control is not used.
Power cycle the CNC control after parameter modification and verify alarm clears. Check DIAGNOSIS > SERVO > axis status to confirm composite control is functioning.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.