FANUC codes
FANUCProgram/G-codeAdvanced30-90 minutes

350

Fanuc Alarm 350 - PARAMETER OF INDEX OF SYNCHRONOUS CONTROL AXIS SET ERROR

PARAMETER OF INDEX OF SYNCHRONOUS CONTROL AXIS SET ERROR

Fanuc PS350: The parameter setting for synchronous control axis index is incorrect. The axis pair configured for synchronous control has an invalid or conflicting parameter value.

Root Cause Summary

Alarm 350 SYNCHRONOUS CONTROL AXIS SET ERROR occurs when parameter 8180 contains an invalid axis number for synchronous control operation. This typically happens after parameter changes, axis reconfiguration, or when attempting to synchronize axes that don't exist or aren't properly configured in the system.

Safety

  • Home position may be incorrect

Causes and Fixes

  1. 1

    Navigate to SYSTEM > PARAM and check parameter 8180. Verify the axis number set matches an actual controlled axis in your system (typically 1-8 for standard configurations).

  2. 2

    Check parameter 1020 (number of controlled axes) to confirm total axes available. Parameter 8180 value must not exceed this number and must reference a valid axis.

  3. 3

    Verify parameter 8181 (master axis for synchronous control) is also set correctly and references a different valid axis than parameter 8180.

  4. 4

    Correct parameter 8180 to a valid axis number (typically Z-axis is axis 3, but verify against your machine configuration). Power cycle the control after parameter write to clear the alarm.

    Parameter write enable (bit 0 of parameter 3202) must be set to 1. Record original values before making changes.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Servo amplifier replacement needed
  • ·Multiple axes showing same alarm

Prevention

  • Regular encoder cable inspection during PM
  • Maintain proper cable strain relief
  • Keep encoder connections clean and dry
  • Monitor encoder diagnostic parameters monthly

Common Mistakes

  • Assuming cable is good without continuity test
  • Ignoring encoder LED status indicators
  • Incorrect parameter restoration after amplifier replacement
  • Not performing encoder calibration after replacement

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.