Fanuc Alarm 130 - NC AND PMC AXIS CONFLICTED
Fanuc Alarm 130 occurs when the CNC (NC) attempts to control an axis simultaneously with PMC (ladder) control, creating a command conflict. This typically happens when PMC axis control is active via ladder logic while an NC program tries to move the same axis, or when switching between control modes is not properly sequenced.
Fanuc Alarm 130 - NC AND PMC AXIS CONFLICTED
NC AND PMC AXIS CONFLICTED
Fanuc PS130: A conflict occurred between NC axis control and PMC axis control. An axis commanded by the NC program is also being controlled by the PMC ladder logic simultaneously.
Root Cause Summary
Fanuc Alarm 130 occurs when the CNC (NC) attempts to control an axis simultaneously with PMC (ladder) control, creating a command conflict. This typically happens when PMC axis control is active via ladder logic while an NC program tries to move the same axis, or when switching between control modes is not properly sequenced.
Safety
Causes and Fixes
Check DIAGNOSIS screen > PMC > Signal Status to verify G address signals controlling the affected axis. Look for G000-G003 (axis selection) and associated control signals that may still be active.
Review parameters 8010-8013 (PMC axis control axis number settings) to identify which axes are designated for PMC control. Cross-reference with your NC program to confirm axis conflict.
Examine ladder logic (PMC > LADDER screen or FAPT Ladder) for axis control sequences. Verify that PMC axis control signals are properly reset (turned OFF) before NC program execution begins, typically using M-codes or sequence flags.
Modify ladder to ensure proper interlock logic between PMC and NC control modes. Use R or K relay flags to create exclusive control zones, ensuring only one control method is active at a time.
Improper ladder modification can affect machine safety interlocks. Document all changes and test in single-block mode.
Call a technician if:
Prevention