Fanuc Alarm 135 - Absolute Position Lost
Fanuc Alarm 135 - Absolute Position Lost typically occurs when the machine's absolute position reference is disrupted due to a dead battery, encoder malfunction, or unexpected power loss. The most likely fix is replacing the battery, as it is the most common cause, followed by re-referencing the machine to restore position data.
Fanuc Alarm 135 - Absolute Position Lost
Absolute Reference Error
Fanuc alarm 135: Absolute Reference Error. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 135 - Absolute Position Lost typically occurs when the machine's absolute position reference is disrupted due to a dead battery, encoder malfunction, or unexpected power loss. The most likely fix is replacing the battery, as it is the most common cause, followed by re-referencing the machine to restore position data.
Safety
Causes and Fixes
Check Battery Voltage
Locate the battery compartment on the control unit or servo amplifier. Use a multimeter to measure the voltage; it should be within the manufacturer's specified range (typically 3.6V for lithium batteries).
Always keep spare batteries on hand with the correct part number for your Fanuc model.
Ensure machine power is off before accessing the battery compartment to avoid electrical shock.
Replace Battery if Low
If voltage is below spec or battery is over 2 years old, replace it with a compatible battery. Follow Fanuc manual for correct replacement procedure to avoid data loss.
Replace the battery with power on if possible to retain position data temporarily, if supported by your model.
Incorrect battery type can damage the system; double-check part compatibility.
Verify Alarm Clearance
After replacement, power cycle the machine and check if Alarm 135 clears. If it persists, proceed to re-referencing the machine as position data may still be lost.
Document the date of battery replacement for future maintenance scheduling.
Do not operate the machine until the alarm is cleared to avoid positional errors.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.