FANUC codes
FANUCProgram/G-codeIntermediate5-30 minutes

049

Fanuc 49 - Reference return point error

REFERENCE RETURN POINT ERROR

Fanuc PS program alarm 49: REFERENCE RETURN POINT ERROR. This alarm is triggered by an illegal or incorrectly formatted command in the part program, or a programming condition that the Fanuc control cannot execute.

Root Cause Summary

Alarm 049 occurs when the CNC attempts to execute a program requiring machine reference point data, but one or more axes have not completed their reference return (homing) sequence. This alarm can also trigger if the reference position data is lost or corrupted in memory, or if the program calls for an absolute position command before proper homing has been established.

Safety

  • Verify corrected program or parameters before resuming machining

Causes and Fixes

  1. 1

    Check the position display screen for asterisks (*) next to axis position values, which indicate that axis has not been homed.

  2. 2

    Switch the machine to MANUAL or JOG mode and perform reference return (home) operation for all axes showing asterisks.

    Ensure machine area is clear and all safety guards are in place before moving axes.

  3. 3

    Verify all axis position displays no longer show asterisks and display valid reference positions.

  4. 4

    Reset the alarm and attempt to run the program again in AUTO mode.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.