Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

61333

Siemens 840D 61333 - Channel Block: Check calibration facility number

Channel Block: Check calibration facility number

Parameter _CALNUM is too large. Alarm is triggered: CYCLE973. Remedy: Reduce _CALNUM to a permissible value or increase maximum value _CVAL[2] in GUD6.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • _CALNUM parameter value exceeds the maximum calibration facility number defined in _CVAL[2]
  • GUD6 maximum calibration value _CVAL[2] set too low for current machining requirements
  • Incorrect calibration facility number assigned during part program or offset table setup
  • Machine configuration changes made without updating corresponding calibration limits
  • Corrupted or manually edited parameter values in machine data or part program

Troubleshooting Steps

  1. 1Check current _CALNUM parameter value and compare against _CVAL[2] maximum limit in GUD6 to identify the overage
  2. 2Review the part program block triggering CYCLE973 and verify the calibration facility number is appropriate for the operation
  3. 3Increase _CVAL[2] in GUD6 to accommodate the required _CALNUM value, or reduce _CALNUM to stay within existing limits
  4. 4Verify machine configuration and calibration facility definitions match current setup; restore from backup if parameters were recently modified
  5. 5Reset affected parameters to factory defaults if corruption is suspected, then reconfigure according to machine specifications