axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-60 minutes
Siemens 840D 61342 - Channel Block: Invalid software version or wrong format entered
Alarm can be triggered by following measuring cycles: all measuring cycles. Remedy: Lower than measuring cycle software 6.2:_SI[1] in GUD6 has no value or a value < 3 Higher than measuring cycle software 6.3: Upgrade NCK software version.
Siemens 840D 61342 - Channel Block: Invalid software version or wrong format entered
Channel Block: Invalid software version or wrong format entered
Alarm can be triggered by following measuring cycles: all measuring cycles. Remedy: Lower than measuring cycle software 6.2:_SI[1] in GUD6 has no value or a value < 3 Higher than measuring cycle software 6.3: Upgrade NCK software version.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.