Siemens SINUMERIK codes
Siemens SINUMERIKProbingIntermediate30-120 minutes

61301

Siemens 61301 - Block: Probe not switching

Block: Probe not switching

Siemens SINUMERIK alarm 61301: Block: Probe not switching. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

Alarm 61301 indicates that a measuring cycle (G65, G66, G67, or similar probe cycles) completed its full traversal distance without detecting an edge trigger at the configured measuring input. This occurs when the probe signal fails to transition at the expected setpoint, preventing the NCK from capturing the measurement position.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Verify physical probe connectivity and continuity. Check probe connector at spindle head and PLC input module terminals. Use multimeter to confirm probe resistance changes from open to closed circuit when manually actuated.

    Power down machine before measuring probe continuity.

  2. 2

    Navigate to Diagnostics > Inputs/Outputs in SINUMERIK 840D control panel. Monitor the configured measuring input bit (typically MP 34070 setpoint) in real-time while manually triggering the probe. Confirm signal state change from 0 to 1 or 1 to 0.

  3. 3

    Check PLC input module assignment in Hardware Configuration. Verify measuring input is configured to correct digital input module slot and pin. Cross-reference with machine builder's wiring diagram.

  4. 4

    If signal appears in diagnostics but alarm still occurs, verify measuring input edge polarity matches probe type. Confirm MD 34075 (measuring input filter time) is not set too high (typical: 5-10 ms), which can suppress short pulses.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.