Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate20-45 minutes

61111

Siemens 61111 - Block : Infeed width > Tool diameter

Block: Infeed width > Tool diameter

The programmed infeed width is greater than the diameter of the active tool Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The programmed infeed width is greater than the diameter of the active tool

Troubleshooting Steps

  1. 1Infeed width must be reduced.
  2. 2Clear alarm with the RESET key. Restart part program Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.