Siemens 840D 6035 - Instead of KB the system has only KB of free user memory of type
Alarm 6035 indicates insufficient free user memory in the NCK after cold start, where actual available memory falls below the Siemens-specified minimum for the control variant. This is an informational alarm that does not halt NCK functions but signals memory configuration issues that may impact program capacity or real-time performance.
Siemens 840D 6035 - Instead of KB the system has only KB of free user memory of type
Instead of KB the system has only KB of free user memory of type
Siemens SINUMERIK alarm 6035: Instead of KB the system has only KB of free user memory of type. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6035 indicates insufficient free user memory in the NCK after cold start, where actual available memory falls below the Siemens-specified minimum for the control variant. This is an informational alarm that does not halt NCK functions but signals memory configuration issues that may impact program capacity or real-time performance.
Safety
Causes and Fixes
Access NCK machine data: Menu → Diagnostics → Machine Data → MD10200 and MD10210. Document current values.
Do not modify without recording original settings.
Cross-reference configured values against the control variant specification in the hardware manual (typically 840D 4GB systems allocate ~2000 KB NC program memory by default).
Reduce MD10200/MD10210 by 10-15% increments if they exceed variant baseline. Perform cold start (NCK power cycle) and monitor free memory report in diagnostics.
Verify sufficient space for all part programs before reducing allocation.
Confirm alarm clears after cold start. If persistent, document free memory value reported and compare to MD1000 (available memory) specification.