Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

6035

Siemens 840D 6035 - Instead of KB the system has only KB of free user memory of type

Instead of KB the system has only KB of free user memory of type

Siemens SINUMERIK alarm 6035: Instead of KB the system has only KB of free user memory of type. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

Alarm 6035 indicates insufficient free user memory in the NCK after cold start, where actual available memory falls below the Siemens-specified minimum for the control variant. This is an informational alarm that does not halt NCK functions but signals memory configuration issues that may impact program capacity or real-time performance.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access NCK machine data: Menu → Diagnostics → Machine Data → MD10200 and MD10210. Document current values.

    Do not modify without recording original settings.

  2. 2

    Cross-reference configured values against the control variant specification in the hardware manual (typically 840D 4GB systems allocate ~2000 KB NC program memory by default).

  3. 3

    Reduce MD10200/MD10210 by 10-15% increments if they exceed variant baseline. Perform cold start (NCK power cycle) and monitor free memory report in diagnostics.

    Verify sufficient space for all part programs before reducing allocation.

  4. 4

    Confirm alarm clears after cold start. If persistent, document free memory value reported and compare to MD1000 (available memory) specification.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.