axismd.ai
Siemens SINUMERIK Controller
Parameter · Intermediate · 30-120 minutes
Siemens 840D 6020 - Machine data have been changed - now memory is reorganized
Alarm 6020 fires when machine data parameters affecting NC user memory allocation (MD10100-MD10110 range) have been modified, triggering automatic memory reorganization by the NCK data management system. This is an informational alarm indicating successful memory restructuring, not a critical fault, but confirms that MD changes have altered the memory layout.
Siemens 840D 6020 - Machine data have been changed - now memory is reorganized
Machine data have been changed - now memory is reorganized
Siemens SINUMERIK alarm 6020: Machine data have been changed - now memory is reorganized. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6020 fires when machine data parameters affecting NC user memory allocation (MD10100-MD10110 range) have been modified, triggering automatic memory reorganization by the NCK data management system. This is an informational alarm indicating successful memory restructuring, not a critical fault, but confirms that MD changes have altered the memory layout.
Safety
Causes and Fixes
Access Machine Data Editor: Select 'Diagnostics' > 'Machine Data' > navigate to MD10100/MD10101 in the '1' (General) category to verify recent changes to memory allocation parameters.
Document the current values and compare against system documentation. Standard values typically range MD10100: 200000-500000 bytes (NCK memory) and MD10101: 100000-300000 bytes (program memory) depending on system configuration.
Confirm alarm clears automatically after one cycle or power cycle. If alarm persists beyond one startup sequence, check error log via 'Diagnostics' > 'Alarms' for secondary error messages indicating memory corruption.
Do not modify MD10100/MD10101 during active program execution or during memory-intensive operations (large file transfers).
If changes were unintended, restore backup Machine Data file from known-good state using 'Utilities' > 'Backup/Restore' and perform cold restart (POWER ON/OFF cycle).
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.