Siemens 300860 - Axis drive generator mode: emergency retraction speed > max.
This alarm occurs when the emergency retraction speed in MD1639 exceeds the maximum motor speed in MD1146. Adjust the retraction speed or consult machine data to resolve.
Siemens 300860 - Axis drive generator mode: emergency retraction speed > max.
Axis drive generator mode: emergency retraction speed > max.
The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED (emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) Control reaction: Interface signals are set. Alarm display.
Root Cause Summary
This alarm occurs when the emergency retraction speed in MD1639 exceeds the maximum motor speed in MD1146. Adjust the retraction speed or consult machine data to resolve.
Safety
Causes and Fixes
Check machine data
Access MD1639 and compare the emergency retraction speed with MD1146 ($MD_MOTOR_MAX_ALLOWED_SPEED).
Adjust retraction speed
Reduce the value in MD1639 to be within the limit specified in MD1146.
Reset and test
Clear the alarm and test the program to confirm the issue is resolved.
Call a technician if:
Prevention