Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

26032

Siemens 26032 - Axis master-slave not configured

Axis master-slave not configured

The master-slave coupling could not be activated because of incomplete configuration Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The master-slave coupling could not be activated because of incomplete configuration

Troubleshooting Steps

  1. 1Check the current configuration of the master-slave coupling.
  2. 2The configuration can be modified via the MASLDEF instruction or the machine data MD37250 $MA_MS_ASSIGN_MASTER_SPEED_CMD and MD37252 $MA_MS_ASSIGN_MASTER_TORQUE_CTR.
  3. 3Clear alarm with the RESET key. Restart part program Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.