Siemens SINUMERIK codes
Siemens SINUMERIKSpindleIntermediate15-30 minutes

17010

Siemens 17010 - Block no memory left

Block no memory left

Siemens SINUMERIK alarm 17010: Block no memory left. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 17010 occurs when the NC kernel detects the tool-in-spindle monitoring signal (typically DB31.DBX1.0 or similar) indicates no tool present when the part program or machine cycle expects a clamped tool. This safety interlock prevents spindle rotation or axis movement without proper tool engagement to protect the drawbar mechanism and prevent tool drops.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check tool holder seating

    Manually inspect tool holder insertion depth in spindle taper. Verify proper BT/CAT/HSK engagement and no debris in taper.

    Ensure spindle is stopped and in safe position before manual inspection

  2. 2

    Verify drawbar operation

    Access Service → Spindle → Manual and test drawbar clamp/unclamp cycles. Monitor hydraulic pressure if equipped.

    Listen for distinct clamp engagement sound - should be crisp and consistent

  3. 3

    Check proximity sensor position

    Verify inductive sensor gap to drawbar target (typically 1-3mm). Adjust sensor mounting bracket if necessary.

    Use feeler gauges for precise gap measurement when drawbar is extended

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drawbar mechanical failure suspected
  • ·PLC programming changes required
  • ·Hydraulic system repairs needed

Prevention

  • Regular proximity sensor cleaning and gap verification
  • Periodic drawbar force testing
  • Keep tool holder tapers clean and undamaged
  • Monitor hydraulic pressure trends

Common Mistakes

  • Ignoring intermittent sensor signals
  • Disabling tool monitoring without understanding safety implications
  • Incorrect sensor gap adjustment
  • Not checking tool holder condition during troubleshooting

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.