Siemens 840D 17110 - Channel block digital output no. not activated
An attempt was made to read or set a digital NCK output (connector X 121) via the system variable $A_OUT [n] with the index [n] greater than the specified upper limit in the NCK machine data 10360 FASTIO_DIG_NUM_OUTPUTS.
Siemens 840D 17110 - Channel block digital output no. not activated
Channel block digital output no. not activated
An attempt was made to read or set a digital NCK output (connector X 121) via the system variable $A_OUT [n] with the index [n] greater than the specified upper limit in the NCK machine data 10360 FASTIO_DIG_NUM_OUTPUTS.