Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-45 minutes

14026

Siemens 14026 - Block motion synchronous action: invalid polynomial number in the

Block motion synchronous action: invalid polynomial number in the

An FCTDEF command was programmed with a polynomial number that exceeds the maximum value set in MD28252 $MC_MM_NUM_FCTDEF_ELEMENTS Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • An FCTDEF command was programmed with a polynomial number that exceeds the maximum value set in MD28252 $MC_MM_NUM_FCTDEF_ELEMENTS

Troubleshooting Steps

  1. 1Modify part program.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.