Siemens 840D 14040 - Channel block error in end point of circle
In circular interpolation, either the circle radii for the initial point and the end point are further apart, or the circle center points are further apart, than specified in the machine data. 1. In circle radius programming the starting and end points are identical, thus the circle position is not
Siemens 840D 14040 - Channel block error in end point of circle
Channel block error in end point of circle
In circular interpolation, either the circle radii for the initial point and the end point are further apart, or the circle center points are further apart, than specified in the machine data. 1. In circle radius programming the starting and end points are identical, thus the circle position is not
Safety
Refer to Siemens documentation
Ensure qualified technician performs repairs
Common Causes
Circular interpolation programmed with starting and ending points that are identical or too close together, making circle center calculation ambiguous
Machine data tolerance settings for circle radius deviation or center point deviation are too tight for the programmed geometry
Rounding errors or insufficient decimal precision in part program coordinates causing calculated radii or centers to exceed tolerance bands
Incorrect G-code syntax for arc commands (G02/G03) with mismatched radius values between entry and exit points
Troubleshooting Steps
1Review the part program block referenced in the alarm message; verify that start point and end point of the circular interpolation are not identical and are separated by sufficient distance
2Check machine data parameters governing circle interpolation tolerances (typically found in axis-specific or general interpolation settings); verify they are appropriate for your part tolerance requirements
3Recalculate or regenerate the part program with higher decimal precision for arc endpoints and ensure radius values (R parameter or I/J/K values) are consistent with actual geometry
4Test with a simple diagnostic G-code circle (e.g., full circle at known coordinates) to isolate whether the issue is program-specific or a systematic machine data problem
5If using CAM software, regenerate toolpath and verify post-processor settings are outputting coordinates with adequate precision and correct arc format for 840D/828D controller