Siemens 14092 - Block axis is wrong axis type

Block axis is wrong axis type

One of the following programming errors has occurred: 1. The keyword WAITP(x) "Wait with block change until the specified positioning axis has reached its end point" has been used for an axis that is not a positioning axis. 2. G74 "Reference point approach from the program" has been programmed for a spindle. (Only axis addresses are permitted). 3. The keyword POS/POSA has been used for a spindle. (The keywords SPOS and SPOSA must be programmed for spindle positioning). 4. If the alarm occurs with the "Rigid tapping" function (G331), the following causes are conceivable: - The master spindle is not in position-controlled mode. - Incorrect master spindle - Master spindle without encoder 5. An axis name was programmed which no longer exists (e.g. when using axial variables as an index). Or NO_AXIS has been programmed as an index. 6. If 14092 is output as a note with alarm 20140 Motion-synchronous action: traversing of command axis, the following causes are possible: - The axis is currently being traversed by the NC program already. - An overlaid movement is active for the axis. - The axis is active as following axis of a coupling. - An interpolation compensation such as a temperature compensation is active for the axis Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Spindle hazard: ensure the spindle is at standstill before working near it; follow lockout/tagout procedures.

Common Causes

  • One of the following programming errors has occurred: 1.
  • The keyword WAITP(x) "Wait with block change until the specified positioning axis has reached its end point" has been used for an axis that is not a positioning axis.
  • 2.

Troubleshooting Steps

  1. 1Correct the part program according to which of the above errors is involved.
  2. 2
  3. 3Clear alarm with NC START or RESET key and continue the program