Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate20-40 minutes

10942

Siemens 840D 10942 - Channel block curve table: illegal instruction during definition

Channel block curve table: illegal instruction during definition

Various illegal command sequences cause the output of this alarm during the definition of the curve table. For example, it is impermissible to terminate definition of a curve table with M30 before programming the CTABEND command.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • M30 or program end command issued before CTABEND statement in curve table definition
  • Incomplete or malformed curve table syntax with missing required commands
  • Illegal command sequences within the curve table definition block
  • CTAB command parameters contain unsupported or invalid instruction syntax

Troubleshooting Steps

  1. 1Review the program listing for the specified channel, block, and curve table to locate the M30 or program termination command
  2. 2Verify that CTABEND command is present and correctly positioned immediately before any M30 or program end statement
  3. 3Check curve table definition syntax against machine documentation to ensure all required parameters and commands are present
  4. 4Examine the curve table for any unsupported G-code or M-code instructions that may be embedded within the definition block
  5. 5Reload the corrected program and re-execute to verify the alarm clears

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.