Okuma OSP Alarm D 4711 - Spindle motor not ready to start
A spindle start command was given before the spindle drive finished its power-up self-check and signaled ready. The drive needs a few seconds after power-on or after a level A alarm reset before it can accept a start command. It can also mean the drive never sent its ready signal because of a wiring or drive unit fault.
Okuma OSP Alarm D 4711 - Spindle motor not ready to start
Spindle motor not ready to start
A spindle start command was given before the spindle drive finished its power-up self-check and signaled ready. The drive needs a few seconds after power-on or after a level A alarm reset before it can accept a start command. It can also mean the drive never sent its ready signal because of a wiring or drive unit fault.