Okuma OSP Alarm C 3716 - XA-axis overload
The X-axis of the A turret exceeded the overload limit set on its load detection meter relay for longer than the preset period, so the control tripped the axis. Detection is active only during the program blocks bracketed by the M135 (ON) and M134 (OFF) commands.
Okuma OSP Alarm C 3716 - XA-axis overload
XA-axis overload
The X-axis of the A turret exceeded the overload limit set on its load detection meter relay for longer than the preset period, so the control tripped the axis. Detection is active only during the program blocks bracketed by the M135 (ON) and M134 (OFF) commands.