Okuma OSP Controller
Spindle · Intermediate
Okuma OSP Alarm B 2709 - Sub-spindle synchronization interlock
The control rejected an M151 sub-spindle synchronized rotation command because the machine conditions required for synchronization were not met. Either both spindle chucks were clamped at the same time, or the command was issued while the C-axis was still engaged.
Okuma OSP Alarm B 2709 - Sub-spindle synchronization interlock
Sub-spindle synchronization interlock
The control rejected an M151 sub-spindle synchronized rotation command because the machine conditions required for synchronization were not met. Either both spindle chucks were clamped at the same time, or the command was issued while the C-axis was still engaged.