KUKA Robot codes
KUKA RobotOvertravel/LimitIntermediate

KRC0615

KUKA Robot KRC0615 - Value range exceeded

Value range exceeded

The WAIT_SEC command in the KRL program has specified a wait duration that exceeds the maximum allowable value. The wait time expressed in basic clock rate cycles is greater than 2147483647, which overflows the signed 32-bit integer range. Reduce the wait time or break the operation into smaller intervals.

Common Causes

  • Wait time calculated using incorrect unit conversion from seconds to clock cycles
  • Variable overflow due to mathematical error in computing the wait duration
  • Direct assignment of an excessively large integer value to the WAIT_SEC time parameter
  • Loop counter or calculation generating accumulating wait times without bounds checking
  • Copy-paste error introducing an unintended large numeric value into the WAIT_SEC command

Troubleshooting Steps

  1. 1Review the KRL code line containing the WAIT_SEC command to identify the time value being specified
  2. 2Calculate the maximum allowable wait time in seconds based on the basic clock rate of the KRC4 system
  3. 3If the intended wait is longer than the maximum, split it into multiple WAIT_SEC commands in sequence
  4. 4Verify variable declarations and mathematical expressions that calculate wait times to prevent overflow
  5. 5Use the KRC4 debugger in the smartPAD to step through the code and inspect actual variable values
  6. 6Add runtime validation logic to check wait time values before passing them to WAIT_SEC commands