KUKA Robot KRC0020 - External Emergency Stop Pressed

External Emergency Stop Pressed

An external Emergency Stop device in the safety circuit has been activated or the safety loop continuity has been broken at a connection point outside the KRC4 cabinet. The dual-channel safety monitoring has detected at least one E-Stop button pressed, safety gate open, or light curtain interruption. Robot motion is halted and all servo drives are disabled with brakes applied.

Common Causes

  • Operator pressed mushroom-head Emergency Stop button on pendant, control panel, or cell perimeter station
  • Safety gate or access door interlock switch opened due to personnel entry or mechanical misalignment of gate position sensor
  • Light curtain, safety scanner, or area monitoring device triggered by object or person entering defined safety zone
  • Broken or disconnected wiring in external E-Stop series chain between multiple stations causing open circuit condition
  • External safety relay or contactor (customer-supplied) in the loop de-energized due to power loss or internal coil failure

Troubleshooting Steps

  1. 1Step 1: Physically inspect all visible Emergency Stop buttons around the cell to identify which device is mechanically latched in pressed position
  2. 2Step 2: Check status of all safety gates and access doors to verify they are fully closed and interlock switches are making proper contact
  3. 3Step 3: Review the smartPAD display for specific safety device identifier if system is configured with monitored E-Stop channels showing source location
  4. 4Step 4: Reset all latched E-Stop buttons by rotating mushroom heads clockwise and verify safety gate closure then press Acknowledge button on smartPAD
  5. 5Step 5: If alarm persists after reset use multimeter to trace 24VDC through external safety circuit measuring voltage drop across each E-Stop station in series
  6. 6Step 6: Check external safety relay panel for tripped relays or blown fuses in 24V safety supply and verify enabling switch on smartPAD is functional after full circuit reset

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.