Heidenhain codes
HeidenhainSafetyIntermediate30-120 minutes

330-00F6

HEIDENHAIN 330-00F6 - FS configuration with a parameter whose value cannot be accepted

FS configuration with a parameter whose value cannot be accepted

This error condition indicates fs configuration with a parameter whose value cannot be accepted. The control has detected an issue that requires attention before normal operation can resume.

Root Cause Summary

Alarm 330-00F6 occurs when the FS (Functional Safety) configuration attempts to set the speedPosComptype parameter to 'noComp' which is not permitted in safety-critical applications. This safety parameter controls speed and position compensation and must have proper compensation enabled for safe machine operation.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access FS Configuration Menu

    Navigate to MOD > System Parameters > FS Configuration to access functional safety settings.

    Only qualified personnel should modify FS safety parameters

  2. 2

    Check speedPosComptype Parameter

    Locate CfgAxParSafety section and verify speedPosComptype value. Change from 'noComp' to appropriate compensation type (linear, nonlinear, or table).

    Document original settings before making changes for rollback purposes

  3. 3

    Validate Safety Configuration

    Use TNC's built-in safety validation to verify the new speedPosComptype setting meets FS requirements before saving.

    Invalid safety configurations can cause machine lockout

  4. 4

    Restart Control System

    Perform controlled shutdown and restart to apply new FS configuration parameters.

    Monitor startup sequence for any additional safety-related alarms

Service Recommendedmedium confidence

Call a technician if:

  • ·FS safety parameters involved
  • ·Machine safety certification required
  • ·Unfamiliar with functional safety requirements

Prevention

  • Validate FS configurations before deployment
  • Maintain backup copies of working FS configurations
  • Document all safety parameter changes
  • Regular FS configuration audits

Common Mistakes

  • Disabling compensation without understanding safety implications
  • Copying FS configurations between different machine types
  • Ignoring software version compatibility for FS parameters
  • Modifying safety parameters without proper authorization

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.