Safety · Intermediate · 30-120 minutes
HEIDENHAIN 330-00F5 - Axis not at test position
Alarm 330-00F5 occurs when the TNC safety system detects that an axis is not positioned within the acceptable tolerance of its defined test position during a safety check routine. This typically happens during machine startup, reference point return, or safety validation cycles when the actual axis position exceeds the positionDiffRef parameter tolerance from the expected positionMatch value in CfgAxisSafety.
HEIDENHAIN 330-00F5 - Axis not at test position
Axis not at test position
The axis is not at the required test position. This may be due to positioning errors or incorrect axis direction configuration.
Root Cause Summary
Alarm 330-00F5 occurs when the TNC safety system detects that an axis is not positioned within the acceptable tolerance of its defined test position during a safety check routine. This typically happens during machine startup, reference point return, or safety validation cycles when the actual axis position exceeds the positionDiffRef parameter tolerance from the expected positionMatch value in CfgAxisSafety.
Safety
Causes and Fixes
Check current axis position
Press POS key to display current axis positions and compare with expected test position values.
Use the position display in incremental mode to see exact deviations
Access CfgAxisSafety parameters
Navigate to MOD > System Parameters > CfgAxisSafety and check positionMatch and positionDiffRef values for the affected axis.
Only modify safety parameters if you have proper authorization and documentation
Verify tolerance settings
Compare the position difference against positionDiffRef parameter - increase tolerance if mechanically acceptable or reposition axis to within tolerance.
Document original values before making any changes
Reset alarm and test
Press CE key to clear alarm, then execute reference point return (G74) to verify axis reaches correct test position.
Ensure machine area is clear before axis movement
Call a technician if:
Prevention