HEIDENHAIN 330-00C9 - Error during activation of an FS configuration

Error during activation of an FS configuration

The safety self-test detected an error. A required signal was not properly set or detected by the HSCI component.

Root Cause Summary

HEIDENHAIN alarm 330-00C9 occurs when safety-critical machine parameters related to functional safety monitoring are modified after the FS (Functional Safety) self-test has already begun. The TNC system prevents changes to brake test timing and self-test intervals during active safety validation to maintain system integrity.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check FS self-test status

    Press MOD key, select 'Machine' menu, navigate to 'Functional Safety' to verify if self-test is currently active or pending.

    The FS status display shows real-time self-test progress and remaining time

  2. 2

    Wait for self-test completion

    Allow the current FS self-test cycle to complete fully before attempting any parameter changes. Monitor the progress indicator in the FS status screen.

    Never interrupt an active safety self-test as this can compromise machine safety certification

  3. 3

    Modify parameters in safe window

    After self-test completion, access Setup menu > Machine Parameters > Safety Parameters (MP7500-7599) to make required timing adjustments.

    Changes to safety parameters require a complete power cycle and new self-test to take effect

  4. 4

    Initiate new self-test cycle

    Power cycle the TNC system and allow the new FS self-test to run with updated parameters to clear the alarm condition.

DIY Feasiblehigh confidence

Call a technician if:

  • ·FS system status remains failed after multiple power cycles
  • ·Safety certificate validation required
  • ·Brake test hardware malfunction suspected

Prevention

  • Always check FS system status before modifying safety parameters
  • Schedule safety parameter changes during planned maintenance windows
  • Document all safety parameter changes with timestamps
  • Verify FS self-test completion before making configuration changes

Common Mistakes

  • Changing multiple safety parameters simultaneously
  • Modifying parameters during active brake tests
  • Not waiting for FS system initialization after power-up
  • Interrupting self-test cycles to make urgent parameter changes

Seeing Multiple Alarms?